Switching Power Supplies For Wireless Applications |
| |
BM 100 |
|
Environmental
| Operating Temperature : |
0 - 50°C |
| Non-operating Temperature: |
0 - 75°C |
| Humidity: |
5% to 95% non-condensing |
Safety & EMI
| Safety: |
Designed to meet IEC - 1950 |
| EMI: |
FCC Class - B / CISPR22 |
Protectins
| Output Over Voltage: |
PSU Trips on over voltage condition |
| Output Over Load: |
output folds back on over load |
| Short Circuit: |
Gosto hick-up mode on short circuit |
| Battery Rev. Polarity: |
PSU protected throuh internal fuse |
Indications
| Mains On: |
When AC is available |
| Battery On: |
When Battery is supplying power to the Radio |
| Battery Low: |
When Battery voltage is less than 11.4V. |
Output Specifications
| AC Input Voltage range |
170 - 270 V AC |
| AC Input |
3 Pin 5.0 A Power cord |
| DC Output Voltage |
13.5 V DC |
| DC Output Current - Equipment |
10.0 Amps |
| DC Output Current - Battery * |
5.0 Amps |
| Output Ripple ( P-P max ) ** |
< 1 % |
| Output Voltage regulation |
± 3 % |
| Batt. deep discharge cut-off facility |
Optional |
| Dimensions ( W X H X D ) |
190 X 75 X 160 ( In mm ) |
| Weight ( in Kg. ) |
1.9 |
| * Battery current when Radio is not in Transmit mode |
| ** While measuring the Ripple & Noise, 10 µF Elec. Cap and 104 CD Cap to be connected across the output. |
|
|
| |
BM 101 |
|
Environmental
| Operating Temperature : |
0 - 50°C |
| Non-operating Temperature: |
0 - 75°C |
| Humidity: |
5% to 95% non-condensing |
Safety & EMI
| Safety: |
Designed to meet IEC - 1950 |
| EMI: |
FCC Class - B / CISPR22 |
Protectins
| Output Over Voltage: |
PSU Trips on over voltage condition |
| Output Over Load: |
output folds back on over load |
| Short Circuit: |
Gosto hick-up mode on short circuit |
| Battery Rev. Polarity: |
PSU protected throuh internal fuse |
Indications
| Mains On: |
When AC is available |
| Battery On: |
When Battery is supplying power to the Radio |
| Battery Low: |
When Battery voltage is less than 11.4V. |
Output Specifications
| AC Input Voltage range |
170 - 270 V AC |
| AC Input |
3 Pin 5.0 A Power cord |
| DC Output Voltage |
13.5 V DC |
| DC Output Current - Equipment |
15.0 Amps |
| DC Output Current - Battery * |
7.0 Amps |
| Output Ripple ( P-P max ) ** |
< 1 % |
| Output Voltage regulation |
± 3 % |
| Batt. deep discharge cut-off facility |
Optional |
| Dimensions ( W X H X D ) |
190 X 75 X 160 ( In mm ) |
| Weight ( in Kg. ) |
1.9 |
| * Battery current when Radio is not in Transmit mode |
| ** While measuring the Ripple & Noise, 10 µF Elec. Cap and 104 CD Cap to be connected across the output. |
|
|
| |
BM 108A |
|
Environmental
| Operating Temperature : |
0 - 50°C |
| Non-operating Temperature: |
0 - 75°C |
| Humidity: |
5% to 95% non-condensing |
Safety & EMI
| Safety: |
Designed to meet IEC - 1950 |
| EMI: |
FCC Class - B / CISPR22 |
Protectins
| Output Over Voltage: |
PSU Trips on over voltage condition |
| Output Over Load: |
output folds back on over load |
| Short Circuit: |
Gosto hick-up mode on short circuit |
| Battery Rev. Polarity: |
PSU protected throuh internal fuse |
Indications
| Mains On: |
When AC is available |
| Battery On: |
When Battery is supplying power to the Radio |
| Battery Low: |
When Battery voltage is less than 11.4V. |
Output Specifications
| AC Input Voltage range |
170 - 270 V AC |
| AC Input |
3 Pin 5.0 A Power cord |
| DC Output Voltage |
12.0 - 14.0 V DC |
| DC Output Current - Equipment |
15.0 Amps |
| DC Output Current - Battery * |
7.0 Amps |
| Output Ripple ( P-P max ) ** |
< 1 % |
| Output Voltage regulation |
± 3 % |
| Batt. deep discharge cut-off facility |
Available |
| Dimensions ( W X H X D ) |
190 X 75 X 160 ( In mm ) |
| Weight ( in Kg. ) |
1.9 |
| * Battery current when Radio is not in Transmit mode |
| ** While measuring the Ripple & Noise, 10 µF Elec. Cap and 104 CD Cap to be connected across the output. |
|
|
| |
BM 306A |
|
Environmental
| Operating Temperature : |
0 - 50°C |
| Non-operating Temperature: |
0 - 75°C |
| Humidity: |
5% to 95% non-condensing |
Safety & EMI
| Safety: |
Designed to meet IEC - 1950 |
| EMI: |
FCC Class - B / CISPR22 |
Protectins
| Output Over Voltage: |
PSU Trips on over voltage condition |
| Output Over Load: |
output folds back on over load |
| Short Circuit: |
Goes to hick-up mode on short circuit |
| Battery Rev. Polarity: |
PSU protected throuh internal fuse |
Indications
| Mains On: |
When AC is available |
| Battery On: |
When Battery is supplying power to the Radio |
| Battery Low: |
When Battery voltage is less than 11.4V. |
Specifications
| AC Input Voltage range |
170 - 270 V AC |
| AC Input |
3 Pin 5.0 A Power cord |
| DC Output Voltage |
11.0 - 14.0 V DC |
| DC Output Current - Equipment |
20.0 Amps |
| DC Output Current - Battery * |
10.0 Amps |
| Output Ripple ( P-P max ) ** |
< 1 % |
| Output Voltage regulation |
± 3 % |
| Batt. deep discharge cut-off facility |
Available |
| Mattering: |
Analog |
| Dimensions ( W X H X D ) |
270 x 86 x 270 |
| Weight ( in Kg. ) |
3.2 |
| * Battery current when Radio is not in Transmit mode |
| ** While measuring the Ripple & Noise, 10 µF Elec. Cap and 104 CD Cap to be connected across the output. |
|
|
| |
BM 315U |
|
Environmental
| Operating Temperature : |
0 - 50°C |
| Non-operating Temperature: |
0 - 75°C |
| Humidity: |
5% to 95% non-condensing |
Safety & EMI
| Safety: |
Designed to meet IEC - 1950 |
| EMI: |
FCC Class - B / CISPR22 |
Protectins
| Output Over Voltage: |
PSU Trips on over voltage condition |
| Output Over Load: |
output folds back on over load |
| Short Circuit: |
Goes to hick-up mode on short circuit |
| Battery Rev. Polarity: |
PSU protected throuh internal fuse |
Indications
| Mains On: |
When AC is available |
| Battery On: |
When Battery is supplying power to the Radio |
| Battery Low: |
When Battery voltage is less than 11.4V. |
Specifications
| AC Input Voltage range |
170 - 270 V AC or 90 - 135 V AC with changeover switch - Optional |
| AC Input |
IEC 320 Socket |
| DC Output Voltage |
11.0-14.0 V DC |
| DC Output Current - Equipment |
30.0 Amps |
| DC Output Current - Battery * |
10.0 Amps |
| Output Ripple ( P-P max ) ** |
< 1 % |
| Output Voltage regulation |
± 3 % |
| Batt. deep discharge cut-off facility |
Available |
| Mattering: |
Optional |
| Dimensions ( W X H X D ) |
190 x 75 x 160 (In mm) |
| Weight ( in Kg. ) |
3.8 |
| * Battery current when Radio is not in Transmit mode |
| ** While measuring the Ripple & Noise, 10 µF Elec. Cap and 104 CD Cap to be connected across the output. |
|
|
| |
DC 100 |
|
Input Specifications
| DC100: |
20 to 30V |
| DC100B: |
40 to 60V |
| DC100R: |
60 to 110V |
Environmental
| Operating Temperature: |
0 - 50°C |
| Non-operating Temperature: |
0 - 75 °C |
| Humidity: |
5% to 95% non-condensing |
Safety & EMI
| Safety: |
Designed to meet IEC-1950 |
| EMI: |
FCC Class - B / CISPR22 |
Protectins
| Output Over Voltage: |
PSU Trips on over voltage condition |
| Output Over Load: |
output folds back on over load |
| Short Circuit: |
Goes to hick-up mode on short circuit |
| Battery Rev. Polarity: |
PSU protected throuh internal fuse |
Indications
| Output On: |
When output is available |
Specifications
| DC Input Voltage range |
20.0 - 30.0 V DC |
| DC Output Voltage |
13.5 V DC |
| DC Output Current - Equipment |
10.0 Amps |
| Output Ripple ( P-P max ) ** |
< 1 % |
| Output Voltage regulation |
± 3 % |
| Efficiency |
>75% |
| Mattering: |
Optional |
| Dimensions ( W X H X D ) |
190 x 75 x 180 (In mm) |
| Weight ( in Kg. ) |
1.9 |
| * Battery current when Radio is not in Transmit mode |
| ** While measuring the Ripple & Noise, 10 µF Elec. Cap and 104 CD Cap to be connected across the output. |
|
|
| |
VRP 90 |
|
|
Environmental
| Operating Temperature: |
0 - 50°C |
| Non-operating Temperature: |
0 - 75 °C |
| Humidity: |
5% to 95% non-condensing |
Safety & EMI
| Safety: |
Designed to meet IEC-1950 |
| EMI: |
FCC Class - B / CISPR22 |
| International Approvals: |
CE approval in progress |
Protectins
| Output Over Voltage: |
PSU Trips on over voltage condition |
| Output Over Load: |
output folds back on over load |
| Short Circuit: |
Goes to hick-up mode on short circuit |
| Battery Rev. Polarity: |
PSU protected throuh internal fuse |
Indications
| Mains On: |
When AC is available |
| Battery On: |
When Battery is supplying power to the Radio |
| Battery Low: |
When Battery voltage is less than 11.4V |
Specifications
| AC Input Voltage range |
170-270 V AC |
| AC Input |
3 Pin 5.0A Power Card |
| DC Output Voltage |
13.5 V DC |
| DC Output Current - Equipment |
10.0 Amps |
| DC Output Current -
Battery * |
5.0 Amps |
| Output Ripple ( P-P max ) ** |
< 1 % |
| Output Voltage regulation |
± 3 % |
| Batt. deep discharge cut-off facility |
Optional |
| Dimensions ( W X H X D ) |
190 x 75 x 160 (In mm) |
| Weight ( in Kg. ) |
1.9 |
|
|
| |